Регистрация
deal.by
077910 | CIA3SX1R1G08 - фото 1 - id-p93676381
Характеристики и описание

Техническая спецификация в PDF  

Mechanical values and environment

Housing materialPA 6.6
Ambient temperature 0 ... 55 °C
Degree of protectionIP20
Mounting methodMounting rail 35mm according to DIN EN 60715 TH35
Number of read headsmax.1
ConnectionPlug-in screw terminals
Cable length
RS232max.5 m
RS422max.1000 m

Electrical connection ratings

Operating voltage DC 20 ... 24 ... 28 V DC  All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.
Current consumptionmax.100 mA 65 mA
LED indicator
GreenSTATE LED operational
YellowACTIVE LED data carrier active
Connection cross-section 0,14 ... 2,5 mm?

Interface, bus

Data protocol3964R via RS232/RS422
Data rate 9600 kbit/s 28800 kbit/s  Can be selected via DIP switches

Miscellaneous

Additional feature
Moisture test (not condensing) at +50°C and 80% rel. h
Vibration - IEC60068-2-6 amplitude 1mm, 10-55Hz, 3 axes
Shock - IEC60068-2-27 acceleration 30g, 6 shocks per axis, 11ms/half sinewave

in combination withRead head CIT3ASX1N12STandData carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-P

Read distance
With center offset m=0 0 ... 3 ... 6,5 mm  These values apply for the surface installation of the read head and the data carrier.
With center offset m=0 0 ... 3 ... 6 mm  These values apply for the surface installation of the read head and flush installation of the data carrier in iron.
With center offset m=0 0 ... 3 ... 5 mm  These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum.
Center offset
Read distance s = 3 mmmax.2,5 mm  These values apply for the surface installation of the read head and the data carrier.
Write distance s = 3 mmmax.2 mm  These values apply for the surface installation of the read head and the data carrier.
Write distance
With center offset m=0 0 ... 3 ... 6 mm  These values apply for the surface installation of the read head and the data carrier.
With center offset m=0 0 ... 3 ... 5,5 mm  These values apply for the surface installation of the read head and flush installation of the data carrier in iron.
With center offset m=0 0 ... 3 ... 4,5 mm  These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum.

 

По вопросу интересующей Вас продукции, пожалуйста, свяжитесь с нами:

  

8 (029) 555-8-000

  

8 (044) 555-8-000

Был online: Давно
OOO "ФилФар Технолоджи"
Рейтинг не сформирован
10 лет на Deal.by

077910 | CIA3SX1R1G08

Под заказ
Цену уточняйте
Доставка