General specifications | |
|---|---|
| Switching function | Normally closed (NC) |
| Output type | PNP |
| Rated operating distance | 6 mm |
| Installation | quasi flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 4.8 mm |
| Actuating element | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm |
| Reduction factor rAl | 0.28 |
| Reduction factor rCu | 0.2 |
| Reduction factor r304 | 0.7 |
| Reduction factor rBrass | 0.35 |
Nominal ratings | |
| Installation conditions | |
| Operating voltage | 10 ... 30 V DC |
| Switching frequency | 0 ... 800 Hz |
| Hysteresis | 0.06 ... 1.2 mm |
| Reverse polarity protection | yes |
| Short-circuit protection | pulsing |
| Overload resistance | yes |
| Wire breakage protection | yes |
| Surge suppression | yes |
| Ripple | 10 % |
| Voltage drop | ? 2 V |
| Repeat accuracy | 0.3 mm |
| Operating current | 0 ... 200 mA , above 70°C max. 150 mA |
| Off-state current | ? 10 µA |
| No-load supply current | ? 15 mA |
| Switching state indicator | LED, yellow |
Functional safety related parameters | |
| MTTFd | 1740 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Approvals and certificates | |
| EAC conformity | TRCU 020/2011 |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
| Connection type | cable PUR , 2 m |
| Core cross-section | 0.34 mm2 |
| Housing material | brass, nickel-plated |
| Sensing face | PBT |
| Housing diameter | 12 mm |
| Degree of protection | IP67 |
| Mass | 80 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |