Описание оборудования | |
---|---|
Single head system | |
General specifications | |
Sensing range | 80 ... 2000 mm |
Adjustment range | 100 ... 2000 mm |
Dead band | 0 ... 80 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 175 kHz |
Response delay | ? 150 ms |
Indicators/operating means | |
LED green | solid green: monitoring system green flashing: program function |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC , ripple10%SS |
No-load supply current | ? 55 mA |
Input/Output | |
Synchronization | 1 synchronous input 0-level: -UB...+1 V 1-level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: 0,1 ... 28 ms |
Synchronization frequency | |
Input | |
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 k?, pulse duration: ? 1 s |
Output | |
Output type | 1 analog output 4 ... 20 mA |
Default setting | evaluation limit A1: 100 mm evaluation limit A2: 2000 mm |
Resolution | 0.5 mm |
Deviation of the characteristic curve | ± 1 % of full-scale value |
Repeat accuracy | ± 0.1 % of full-scale value |
Load impedance | 0 ... 300 Ohm |
Temperature influence | ± 1.5 % of full-scale value |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | Connector M12 x 1 , 5-pin |
Degree of protection | IP65 |
Material | |
Mass | 100 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |